The cooling device properties, like "#cooling-cells" and "dynamic-power-coefficient", should either be present for all the CPUs of a cluster or none. If these are present only for a subset of CPUs of a cluster then things will start falling apart as soon as the CPUs are brought online in a different order. For example, this will happen because the operating system looks for such properties in the CPU node it is trying to bring up, so that it can register a cooling device. Add such missing properties. Fix other missing properties (clocks, supply, clock latency) as well to make it all work. Signed-off-by: Viresh Kumar <viresh.kumar@xxxxxxxxxx> --- arch/arm/boot/dts/dra74x.dtsi | 10 ++++++++++ 1 file changed, 10 insertions(+) diff --git a/arch/arm/boot/dts/dra74x.dtsi b/arch/arm/boot/dts/dra74x.dtsi index 91e93ab588ca..8f9df09155d8 100644 --- a/arch/arm/boot/dts/dra74x.dtsi +++ b/arch/arm/boot/dts/dra74x.dtsi @@ -18,6 +18,16 @@ compatible = "arm,cortex-a15"; reg = <1>; operating-points-v2 = <&cpu0_opp_table>; + + clocks = <&dpll_mpu_ck>; + clock-names = "cpu"; + + clock-latency = <300000>; /* From omap-cpufreq driver */ + + /* cooling options */ + #cooling-cells = <2>; /* min followed by max */ + + vbb-supply = <&abb_mpu>; }; }; -- 2.15.0.194.g9af6a3dea062 -- To unsubscribe from this list: send the line "unsubscribe linux-omap" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html