From: Sebastian Reichel <sebastian.reichel@xxxxxxxxxxxxxxx> power_supply_am_i_supplied() can return negative error codes. In this case we should assume, that no charger is connected and the battery should be marked as DISCHARGING instead of NOT_CHARGING. Reported-by: Merlijn Wajer <merlijn@xxxxxxxxxx> Signed-off-by: Sebastian Reichel <sebastian.reichel@xxxxxxxxxxxxxxx> --- drivers/power/supply/bq27xxx_battery.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/power/supply/bq27xxx_battery.c b/drivers/power/supply/bq27xxx_battery.c index d99981542a46..7ce60519b1bc 100644 --- a/drivers/power/supply/bq27xxx_battery.c +++ b/drivers/power/supply/bq27xxx_battery.c @@ -1670,7 +1670,7 @@ static int bq27xxx_battery_status(struct bq27xxx_device_info *di, status = POWER_SUPPLY_STATUS_FULL; else if (di->cache.flags & BQ27000_FLAG_CHGS) status = POWER_SUPPLY_STATUS_CHARGING; - else if (power_supply_am_i_supplied(di->bat)) + else if (power_supply_am_i_supplied(di->bat) > 0) status = POWER_SUPPLY_STATUS_NOT_CHARGING; else status = POWER_SUPPLY_STATUS_DISCHARGING; -- 2.16.1 -- To unsubscribe from this list: send the line "unsubscribe linux-omap" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html