Currently the slope and offset values for calculating the hot spot temperature of a particular thermal zone is part of driver data. Pass them here instead and obtain the values while of node parsing. Signed-off-by: Keerthy <j-keerthy@xxxxxx> --- arch/arm/boot/dts/omap443x.dtsi | 4 ++++ 1 file changed, 4 insertions(+) diff --git a/arch/arm/boot/dts/omap443x.dtsi b/arch/arm/boot/dts/omap443x.dtsi index fc6a861..03c8ad9 100644 --- a/arch/arm/boot/dts/omap443x.dtsi +++ b/arch/arm/boot/dts/omap443x.dtsi @@ -71,4 +71,8 @@ }; +&cpu_thermal { + coefficients = <0 20000>; +}; + /include/ "omap443x-clocks.dtsi" -- 1.9.1 -- To unsubscribe from this list: send the line "unsubscribe linux-omap" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html