On Mon, Mar 21, 2016 at 01:04:18AM +0100, Sebastian Reichel wrote: > Right thinking about it, the voltage must also be configured for the > non always-on cases. So it's not a problem with the regulator > framework, but with twl-regulator's probe function, that should take > care of this. Absolutely not! Like all other regulator drivers the twl driver should be taking no decisions about what voltage to set except in response to a set_voltage() call. All the logic about setting voltages is factored out into the core. Please try to understand the abstractions we're using in the framework.