[PATCH] thermal: Switch mode to enabled once the cooling device is bound

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Currently mode is still disabled even after the cooling device is bound
to the appropriate device. Hence changing the mode to enabled as soon as
the cooling device is registered successfully.

Signed-off-by: Keerthy <j-keerthy@xxxxxx>
---
 drivers/thermal/of-thermal.c | 3 +++
 1 file changed, 3 insertions(+)

diff --git a/drivers/thermal/of-thermal.c b/drivers/thermal/of-thermal.c
index 04b1be7..bc84485 100644
--- a/drivers/thermal/of-thermal.c
+++ b/drivers/thermal/of-thermal.c
@@ -163,6 +163,9 @@ static int of_thermal_bind(struct thermal_zone_device *thermal,
 		}
 	}
 
+	/* Now that cooling device is bound enable the thermal device*/
+	data->mode = THERMAL_DEVICE_ENABLED;
+
 	return 0;
 }
 
-- 
1.9.1

--
To unsubscribe from this list: send the line "unsubscribe linux-omap" in
the body of a message to majordomo@xxxxxxxxxxxxxxx