Am 16.06.2015 um 21:17 schrieb Felipe Balbi:
With this patch we try to be as close to 50% duty cycle as possible. The reason for this is that some devices present an erratic behavior with certain duty cycles. One such example is TPS65218 PMIC which fails to change voltages when running @ 400kHz and duty cycle is lower than 34%. The idea of the patch is simple: calculate desired scl_period from requested scl and use 50% for tLow and 50% for tHigh.
... Hmm, and what's about Philips I2C specification 2.1, Jan 2000, Table 5?
PARAMETER SYMBOL STANDARD-MODE FAST-MODE UNIT MIN. MAX. MIN. MAX. LOW period of the SCL clock tLOW 4.7 – 1.3 – µs HIGH period of the SCL clock tHIGH 4.0 – 0.6 – µs
Your signal is in spec (0.85 µs high, 1,65 low). Maybe your TPS65218 is just buggy or signals are bad? -- KR Michael -- To unsubscribe from this list: send the line "unsubscribe linux-omap" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html