Hi, On Mon, Nov 25, 2013 at 08:32:46PM +0200, Ивайло Димитров wrote: > So, AIUI there are 2 options: > > 1. charger driver polls the battery driver every n (60?) seconds. > 2. battery driver sends PSY_EVENT_PROP_CHANGED on every degree > up or down. > > In both cases if the temperature is outside of the safe margins, the > charging should be stopped. ACK. > 2 seems more generic to me, but as rx51-battery is missing the > functionality to send events on temperature change, I guess 1 will > be easier to implement. The temperature must be polled anyway, if the ADC does not support interrupts. > And I think there should be some method (sysfs entry?, /dev/bqxxx > opened?) to tell the charger driver to stop polling the battery > driver once (and if) the userspace has started to take care of the > battery temperature - makes no sense to duplicate the checks IMO. I would just cache the temperature value in the battery driver for a couple of seconds. Then userspace can check for very high temperatures (-> system shutdown) and the charging driver can check for temperatures, which are critical for charging. -- Sebastian