From: Trond Myklebust <trond.myklebust@xxxxxxxxxxxxxxx> If the NFS super block is being unmounted, then we currently may end up telling the server that we've forgotten the layout while it is actually still in use by the client. In that case, just assume that the client will soon return the layout anyway, and so return NFS4ERR_DELAY in response to the layout recall. Fixes: 58ac3e59235f ("NFSv4/pnfs: Clean up nfs_layout_find_inode()") Signed-off-by: Trond Myklebust <trond.myklebust@xxxxxxxxxxxxxxx> --- fs/nfs/callback_proc.c | 17 +++++++++-------- 1 file changed, 9 insertions(+), 8 deletions(-) diff --git a/fs/nfs/callback_proc.c b/fs/nfs/callback_proc.c index f7786e00a6a7..ed9d580826f5 100644 --- a/fs/nfs/callback_proc.c +++ b/fs/nfs/callback_proc.c @@ -137,12 +137,12 @@ static struct inode *nfs_layout_find_inode_by_stateid(struct nfs_client *clp, list_for_each_entry_rcu(lo, &server->layouts, plh_layouts) { if (!pnfs_layout_is_valid(lo)) continue; - if (stateid != NULL && - !nfs4_stateid_match_other(stateid, &lo->plh_stateid)) + if (!nfs4_stateid_match_other(stateid, &lo->plh_stateid)) continue; - if (!nfs_sb_active(server->super)) - continue; - inode = igrab(lo->plh_inode); + if (nfs_sb_active(server->super)) + inode = igrab(lo->plh_inode); + else + inode = ERR_PTR(-EAGAIN); rcu_read_unlock(); if (inode) return inode; @@ -176,9 +176,10 @@ static struct inode *nfs_layout_find_inode_by_fh(struct nfs_client *clp, continue; if (nfsi->layout != lo) continue; - if (!nfs_sb_active(server->super)) - continue; - inode = igrab(lo->plh_inode); + if (nfs_sb_active(server->super)) + inode = igrab(lo->plh_inode); + else + inode = ERR_PTR(-EAGAIN); rcu_read_unlock(); if (inode) return inode; -- 2.30.2