[PATCH 1/2] SUNRPC: Ensure that call_connect times out correctly

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



When the server is unavailable due to a networking error, etc, we want
the RPC client to respect the timeout delays when attempting to reconnect.

Fixes: 561ec1603171 (SUNRPC: call_connect_status should recheck bind..)
Signed-off-by: Trond Myklebust <trond.myklebust@xxxxxxxxxxxxxxx>
---
 net/sunrpc/clnt.c | 8 +++-----
 1 file changed, 3 insertions(+), 5 deletions(-)

diff --git a/net/sunrpc/clnt.c b/net/sunrpc/clnt.c
index 0edada973434..f22d3a115fda 100644
--- a/net/sunrpc/clnt.c
+++ b/net/sunrpc/clnt.c
@@ -1798,10 +1798,6 @@ call_connect_status(struct rpc_task *task)
 	trace_rpc_connect_status(task, status);
 	task->tk_status = 0;
 	switch (status) {
-		/* if soft mounted, test if we've timed out */
-	case -ETIMEDOUT:
-		task->tk_action = call_timeout;
-		return;
 	case -ECONNREFUSED:
 	case -ECONNRESET:
 	case -ECONNABORTED:
@@ -1812,7 +1808,9 @@ call_connect_status(struct rpc_task *task)
 		if (RPC_IS_SOFTCONN(task))
 			break;
 	case -EAGAIN:
-		task->tk_action = call_bind;
+	case -ETIMEDOUT:
+		/* Check if we've timed out before looping back to call_bind */
+		task->tk_action = call_timeout;
 		return;
 	case 0:
 		clnt->cl_stats->netreconn++;
-- 
1.8.5.3

--
To unsubscribe from this list: send the line "unsubscribe linux-nfs" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html