Hi all, next-20111216 (and all later so far) fails to boot on a Power7 blade server like this: calling .serial8250_init+0x0/0x1e0 @ 1 Serial: 8250/16550 driver, 4 ports, IRQ sharing disabled INFO: rcu_sched detected stalls on CPUs/tasks: { 3 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31} (detected by 5, t=6002 jiffies) Call Trace: [c0000003fd9e74e0] [c000000000015054] .show_stack+0x74/0x1c0 (unreliable) [c0000003fd9e7590] [c00000000012ad2c] .__rcu_pending+0x49c/0x4b0 [c0000003fd9e7650] [c00000000012ae94] .rcu_check_callbacks+0x154/0x250 [c0000003fd9e76f0] [c0000000000b8ab4] .update_process_times+0x44/0xa0 [c0000003fd9e7780] [c0000000000fcdbc] .tick_sched_timer+0x7c/0x100 [c0000003fd9e7820] [c0000000000d5b38] .__run_hrtimer+0xb8/0x270 [c0000003fd9e78d0] [c0000000000d6068] .hrtimer_interrupt+0x138/0x2d0 [c0000003fd9e79e0] [c00000000001e4d0] .timer_interrupt+0x130/0x300 [c0000003fd9e7a90] [c0000000000038e4] decrementer_common+0x164/0x180 --- Exception: 901 at .arch_local_irq_restore+0xd8/0x140 LR = .cpu_idle+0x180/0x220 [c0000003fd9e7d80] [c000000000c7c368] wireless_seq_fops+0x109a8/0x2f418 (unreliable) [c0000003fd9e7e20] [c000000000017970] .cpu_idle+0x180/0x220 [c0000003fd9e7ed0] [c0000000008369e8] .start_secondary+0x3a4/0x3b0 [c0000003fd9e7f90] [c0000000000093f4] .start_secondary_prolog+0x10/0x14 There are quite a few more rcu stalls after this and the boot never completes (at least not before our automated test system steps in and reboots the server). So the obvious first place to point the finger would be changes to the 8250 code ... but there is nothing too obvious there. -- Cheers, Stephen Rothwell sfr@xxxxxxxxxxxxxxxx http://www.canb.auug.org.au/~sfr/