On Thu, 4 Sep 2008, Andrew Morton wrote:
>
> <plugs it in>
> 
> cs: pcmcia_socket0: unable to apply power.
> pccard: CardBus card inserted into slot 0
> pci 0000:07:00.0: supports D1
> pci 0000:07:00.0: supports D2
> pci 0000:07:00.0: PME# supported from D1 D2 D3hot D3cold
> pci 0000:07:00.0: PME# disabled
> 
> sony:/home/akpm> lspci -s07:00
> 07:00.0 Ethernet controller: 3Com Corporation 3cCFE575CT CardBus [Cyclone] (rev 10)

Ok, the PCI resource side definitely works.

I've committed the fix as follows.. (the explanation is about three times 
the size, but whatever ;)

As to that "unable to apply power" thing, that's a separate issue.. And 
in fact one that probably doesn't even matter to a CardBus card, since 
cardbus doesn't care about the insane CS state machines anyway.

Anyway, Ivan and Jesse cc'd for the patch, but I committed it, since I 
was involved in causing the bug in the first place.

		Linus

---
commit 5f17cfce5776c566d64430f543a289e5cfa4538b
Author: Linus Torvalds <torvalds@xxxxxxxxxxxxxxxxxxxx>
Date:   Thu Sep 4 01:33:59 2008 -0700

    PCI: fix pbus_size_mem() resource alignment for CardBus controllers
    
    Commit 884525655d07fdee9245716b998ecdc45cdd8007 ("PCI: clean up resource
    alignment management") changed the resource handling to mark how a
    resource was aligned on a per-resource basis.
    
    Thus, instead of looking at the resource number to determine whether it
    was a bridge resource or a regular resource (they have different
    alignment rules), we should just ask the resource for its alignment
    directly.
    
    The reason this broke only cardbus resources was that for the other
    types of resources, the old way of deciding alignment actually still
    happened to work.  But CardBus bridge resources had been changed by
    commit 934b7024f0ed29003c95cef447d92737ab86dc4f ("Fix cardbus resource
    allocation") to look more like regular resources than PCI bridge
    resources from an alignment handling standpoint.
    
    Reported-and-tested-by: Andrew Morton <akpm@xxxxxxxxxxxxxxxxxxxx>
    Cc: Ivan Kokshaysky <ink@xxxxxxxxxxxxxxxxxxxx>
    Cc: Jesse Barnes <jbarnes@xxxxxxxxxxxxxxxx>
    Signed-off-by: Linus Torvalds <torvalds@xxxxxxxxxxxxxxxxxxxx>
---
 drivers/pci/setup-bus.c |    5 +++--
 1 files changed, 3 insertions(+), 2 deletions(-)

diff --git a/drivers/pci/setup-bus.c b/drivers/pci/setup-bus.c
index 82634a2..1aad599 100644
--- a/drivers/pci/setup-bus.c
+++ b/drivers/pci/setup-bus.c
@@ -352,11 +352,12 @@ static int pbus_size_mem(struct pci_bus *bus, unsigned long mask, unsigned long
 				continue;
 			r_size = r->end - r->start + 1;
 			/* For bridges size != alignment */
-			align = (i < PCI_BRIDGE_RESOURCES) ? r_size : r->start;
+			align = resource_alignment(r);
 			order = __ffs(align) - 20;
 			if (order > 11) {
-				dev_warn(&dev->dev, "BAR %d too large: "
+				dev_warn(&dev->dev, "BAR %d bad alignment %llx: "
 				       "%#016llx-%#016llx\n", i,
+				       (unsigned long long)align,
 				       (unsigned long long)r->start,
 				       (unsigned long long)r->end);
 				r->flags = 0;
--