[PATCH 2/4] mmc: sdhci: Remove misleading comment about resets

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



In SDHCI specification section 3.10.1 Error Interrupt Recovery, the flow
chart shows Software Reset for CMD separately and before Software Reset for
DAT, so the comment "Spec says we should do both at the same time" is not
correct. Remove it.

Signed-off-by: Adrian Hunter <adrian.hunter@xxxxxxxxx>
---
 drivers/mmc/host/sdhci.c | 4 ----
 1 file changed, 4 deletions(-)

diff --git a/drivers/mmc/host/sdhci.c b/drivers/mmc/host/sdhci.c
index 34b351363f41..100c7d6be385 100644
--- a/drivers/mmc/host/sdhci.c
+++ b/drivers/mmc/host/sdhci.c
@@ -3059,10 +3059,6 @@ static bool sdhci_request_done(struct sdhci_host *host)
 			/* This is to force an update */
 			host->ops->set_clock(host, host->clock);
 
-		/*
-		 * Spec says we should do both at the same time, but Ricoh
-		 * controllers do not like that.
-		 */
 		sdhci_do_reset(host, SDHCI_RESET_CMD);
 		sdhci_do_reset(host, SDHCI_RESET_DATA);
 
-- 
2.25.1