On 12/2/21 8:30 AM, Al Cooper wrote: > The problem is in the .shutdown callback that was added to the > sdhci-iproc and sdhci-brcmstb drivers to save power in S5. The > shutdown callback will just call the sdhci_pltfm_suspend() function > to suspend the lower level driver and then stop the sdhci system > clock. The problem is that in some cases there can be a worker > thread in the "system_freezable_wq" work queue that is scanning > for a device every second. In normal system suspend, this queue > is suspended before the driver suspend is called. In shutdown the > queue is not suspended and the thread my run after we stop the > sdhci clock in the shutdown callback which will cause the "clock > never stabilised" error. The solution will be to have the shutdown > callback cancel the worker thread before calling suspend (and > stopping the sdhci clock). > > NOTE: This is only happening on systems with the Legacy RPi SDIO > core because that's the only controller that doesn't have the > presence signal and needs to use a worker thread to do a 1 second > poll loop. > > Fixes: 5b191dcba719 ("mmc: sdhci-brcmstb: Fix mmc timeout errors on S5 suspend") > Signed-off-by: Al Cooper <alcooperx@xxxxxxxxx> Acked-by: Florian Fainelli <f.fainelli@xxxxxxxxx> -- Florian