Hi Adrian On 4/9/2021 8:52 PM, Adrian Hunter wrote: > On 9/04/21 5:19 pm, Shah, Nehal-bakulchandra wrote: >> Hi Adrian, >> >> as per JESD84-B50 spec for EMMC 5.0 , HS400 timing sequence is following >> >> In order to switch to HS400 mode, host should perform the following steps: >> 1) Initialize device with “Backward Compatible Timings” >> 2) Select the device with CMD7. >> 3) Read the DEVICE_TYPE [196] field of the Extended CSD register to validate whether the device supports HS400 >> 4) Read the DRIVER_STRENGTH [197] field of the Extended CSD register to find the supported device Driver Strengths. (Note: This step may be skipped if changes of driver strength is not needed) >> 5) Set the “Selected Driver Strength” parameter in the HS_TIMING [185] field of the Extended CSD register to the appropriate driver strength for HS400 operation and set the “Timing Interface” >> parameter to 0x2 to switch to HS200 mode. >> 6) Perform the Tuning Process at the HS400 target operating frequency (Note: tuning process in HS200 mode is required to synchronize the command response on the CMD line to CLK for HS400 operation). >> 7) After the Tuning Process has completed, set the “Timing Interface” parameter in the HS_TIMING [185] field of the Extended CSD register to 0x3 to switch to HS400 mode. >> >> But in case of JESD84-B51 spec EMMC 5.1, HS400 timing sequence is following >> >> 1 )Initialize device with “Backward Compatible Timings”, >> 2) Select the device with CMD7, >> 3) Read the DEVICE_TYPE [196] field of the Extended CSD register to validate whether the device >> supports HS400, >> 4) Read the DRIVER_STRENGTH [197] field of the Extended CSD register to find the supported >> device Driver Strengths, >> NOTE This step may be skipped if changes of driver strength is not needed. >> 5) Set the “Selected Driver Strength” parameter in the HS_TIMING [185] field of the Extended CSD >> register to the appropriate driver strength for HS400 operation and set the “Timing Interface” >> parameter to 0x2 to switch to HS200 mode, >> 6) Perform the Tuning Process at the HS400 target operating frequency, >> NOTE Tuning process in HS200 mode is required to synchronize the command response on the CMD line to >> CLK for HS400 operation. >> 7) Set the “Timing Interface” parameter in the HS_TIMING [185] field of the Extended CSD register to >> 0x1 to switch to High Speed mode and then set the clock frequency to a value not greater than 52 >> MHz, >> 8) Set BUS_WIDTH[183] to 0x06 to select the dual data rate x8 bus mode, >> 9) Set the “Timing Interface” parameter in the HS_TIMING [185] field of the Extended CSD register to >> 0x3 to switch to HS400 mode. >> >> So basically in case EMMC5.1 for HS400 mode selection, there is some difference after tuning. However driver >> existing driver always follow spec of EMMC5.1 . Is there any specific reason for the same? So on our some AMD platforms >> with EMMC5.0 driver is failing but if we modify the driver as per EMCC5.0 sequencing it is passing. So can you please provide >> your inputs? > Hi Nehal Shah > > There was another specification between those two, namely JESD84-B50.1 eMMC 5.01 which has the same procedure as eMMC 5.1 > > AFAICT the 5.0 text was almost immediately "clarified" in 5.01 to match the 5.1 text. > > So we have only 1 HS400 sequence. But some host controllers do have issues, which is why there are additional hooks like ->hs400_downgrade() and ->hs400_prepare_ddr() Sure we will try the same. > Regards > Adrian Regards Nehal