From: Yinbo Zhu <yinbo.zhu@xxxxxxx> Software writing to the Transfer Type configuration register (system clock domain) can cause a setup/hold violation in the CRC flops (card clock domain), which can cause write accesses to be sent with corrupt CRC values. This issue occurs only for write preceded by read. this erratum is to fix this issue. Signed-off-by: Yinbo Zhu <yinbo.zhu@xxxxxxx> Acked-by: Adrian Hunter <adrian.hunter@xxxxxxxxx> --- drivers/mmc/host/sdhci-of-esdhc.c | 3 +++ 1 file changed, 3 insertions(+) diff --git a/drivers/mmc/host/sdhci-of-esdhc.c b/drivers/mmc/host/sdhci-of-esdhc.c index 4e669b4edfc1..9da53e548691 100644 --- a/drivers/mmc/host/sdhci-of-esdhc.c +++ b/drivers/mmc/host/sdhci-of-esdhc.c @@ -1074,6 +1074,9 @@ static int sdhci_esdhc_probe(struct platform_device *pdev) if (esdhc->vendor_ver > VENDOR_V_22) host->quirks &= ~SDHCI_QUIRK_NO_BUSY_IRQ; + if (of_find_compatible_node(NULL, NULL, "fsl,p2020-esdhc")) + host->quirks2 |= SDHCI_QUIRK_RESET_AFTER_REQUEST; + if (of_device_is_compatible(np, "fsl,p5040-esdhc") || of_device_is_compatible(np, "fsl,p5020-esdhc") || of_device_is_compatible(np, "fsl,p4080-esdhc") || -- 2.17.1