From: Yinbo Zhu <yinbo.zhu@xxxxxxx> Software writing to the Transfer Type configuration register (system clock domain) can cause a setup/hold violation in the CRC flops (card clock domain), which can cause write accesses to be sent with corrupt CRC values. This issue occurs only for write preceded by read. this erratum is to fix this issue. Signed-off-by: Yinbo Zhu <yinbo.zhu@xxxxxxx> --- drivers/mmc/host/sdhci-of-esdhc.c | 3 +++ 1 files changed, 3 insertions(+), 0 deletions(-) diff --git a/drivers/mmc/host/sdhci-of-esdhc.c b/drivers/mmc/host/sdhci-of-esdhc.c index 4e669b4..9da53e5 100644 --- a/drivers/mmc/host/sdhci-of-esdhc.c +++ b/drivers/mmc/host/sdhci-of-esdhc.c @@ -1074,6 +1074,9 @@ static int sdhci_esdhc_probe(struct platform_device *pdev) if (esdhc->vendor_ver > VENDOR_V_22) host->quirks &= ~SDHCI_QUIRK_NO_BUSY_IRQ; + if (of_find_compatible_node(NULL, NULL, "fsl,p2020-esdhc")) + host->quirks2 |= SDHCI_QUIRK_RESET_AFTER_REQUEST; + if (of_device_is_compatible(np, "fsl,p5040-esdhc") || of_device_is_compatible(np, "fsl,p5020-esdhc") || of_device_is_compatible(np, "fsl,p4080-esdhc") || -- 1.7.1