On 24.07.2018 17:34, Aapo Vienamo wrote:
Add bindings documentation for pad pull up and pull down offset values to be
programmed before executing automatic pad drive strength calibration.
Signed-off-by: Aapo Vienamo <avienamo@xxxxxxxxxx>
---
.../bindings/mmc/nvidia,tegra20-sdhci.txt | 32 ++++++++++++++++++++++
1 file changed, 32 insertions(+)
diff --git a/Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt b/Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt
index 90c214d..949f616 100644
--- a/Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt
+++ b/Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt
@@ -24,6 +24,7 @@ Required properties:
Optional properties:
- power-gpios : Specify GPIOs for power control
+Optional properties for Tegra210 and Tegra186:
Example:
sdhci@c8000200 {
@@ -45,6 +46,33 @@ Optional properties for Tegra210 and Tegra186:
for controllers supporting multiple voltage levels. The order of names
should correspond to the pin configuration states in pinctrl-0 and
pinctrl-1.
+- pad-autocal-pull-up-offset-3v3, pad-autocal-pull-down-offset-3v3 :
+ Specify drive strength calibration offsets for 3.3 V signaling modes.
+- pad-autocal-pull-up-offset-1v8, pad-autocal-pull-down-offset-1v8 :
+ Specify drive strength calibration offsets for 1.8 V signaling modes.
+- pad-autocal-pull-up-offset-3v3-timeout,
+ pad-autocal-pull-down-offset-3v3-timeout : Specify drive strength
+ used as a fallback in case the automatic calibration times out on a
+ 3.3 V signaling mode.
+- pad-autocal-pull-up-offset-1v8-timeout,
+ pad-autocal-pull-down-offset-1v8-timeout : Specify drive strength
+ used as a fallback in case the automatic calibration times out on a
+ 1.8 V signaling mode.
+- pad-autocal-pull-up-offset-sdr104,
+ pad-autocal-pull-down-offset-sdr104 : Specify drive strength
+ calibration offsets for SDR104 mode.
+- pad-autocal-pull-up-offset-hs400,
+ pad-autocal-pull-down-offset-hs400 : Specify drive strength
+ calibration offsets for HS400 mode.
All of these need an "nvidia," prefix.
+
+ Notes on the pad calibration pull up and pulldown offset values:
+ - The property values are drive codes which are programmed into the
+ PD_OFFSET and PU_OFFSET sections of the
+ SDHCI_TEGRA_AUTO_CAL_CONFIG register.
+ - A higher value corresponds to higher drive strength. Please refer
+ to the reference manual of the SoC for correct values.
+ - The SDR104 and HS400 timing specific values are used in
+ corresponding modes if specified.
Example:
sdhci@700b0000 {
@@ -58,5 +86,9 @@ sdhci@700b0000 {
pinctrl-names = "sdmmc-3v3", "sdmmc-1v8";
pinctrl-0 = <&sdmmc1_3v3>;
pinctrl-1 = <&sdmmc1_1v8>;
+ pad-autocal-pull-up-offset-3v3 = <0x00>;
+ pad-autocal-pull-down-offset-3v3 = <0x7d>;
+ pad-autocal-pull-up-offset-1v8 = <0x7b>;
+ pad-autocal-pull-down-offset-1v8 = <0x7b>;
status = "disabled";
};
--
To unsubscribe from this list: send the line "unsubscribe linux-mmc" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html