On Tue, Jul 24, 2018 at 01:26:34PM +0200, Wolfram Sang wrote: > On Tue, Jul 17, 2018 at 04:52:15PM +0200, Niklas Söderlund wrote: > > When tuning each tap is issued CMD19 twice and the result of both runs > > recorded in host->taps. If the result is different between the two runs > > the wrong sampling clock position was selected. Fix this by merging the > > two runs and only keep the result for each tap if it was good in both > > sets. > > > > Signed-off-by: Niklas Söderlund <niklas.soderlund+renesas@xxxxxxxxxxxx> > > So, I tested this patch without having patch 2 applied and it worked: > > Tested-by: Wolfram Sang <wsa+renesas@xxxxxxxxxxxxxxxxxxxx> > Reviewed-by: Wolfram Sang <wsa+renesas@xxxxxxxxxxxxxxxxxxxx> > > Ulf, I think patches 1 & 3 are good and should be applied to 4.18 with > stable attached. > > And I wonder if it was easier if I'd send you pull requests now that we > are working with even more developers on SDHI? Simon, Niklas, what do > you think? Of course its up to Ulf but from my point of view it would make sense for you to coordinate things at least for now. -- To unsubscribe from this list: send the line "unsubscribe linux-mmc" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html