Hi Chris, On Wednesday 19 of September 2012 01:42:01 Chris Ball wrote: > On Tue, Sep 04 2012, Tomasz Figa wrote: > > Some boards use fixed voltage regulator for vmmc supply (e.g. for eMMC > > memories). MMC_CAP2_BROKEN_VOLTAGE must be enabled for them to operate > > correctly. >> > Is there a reason we can't make this a property on the regulator instead? Is there a reason we can't make this a property of the mmc subsystem? ;) Now, seriously, could you elaborate on this a bit more? Do you mean that a regulator should provide a dummy set voltage operation that would accept any voltage? Best regards, -- Tomasz Figa Samsung Poland R&D Center -- To unsubscribe from this list: send the line "unsubscribe linux-mmc" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html