On Wed, 14 Oct 2009 11:34:42 +0100 David Vrabel <david.vrabel@xxxxxxx> wrote: > > It can be done per-card, the switch to the lower voltage just needs to > be deferred. Initially set the voltage to a standard one that's > supported by the card and host. After the card is fully initialized and > enumerated, have a hook for per-card fixups. For the particular > non-standard card in question, this would then reduce the voltage to 1.8V. > In theory. But it would require a bit of redesign of the code as it would have to restart the whole init again. Rgds -- -- Pierre Ossman WARNING: This correspondence is being monitored by the Swedish government. Make sure your server uses encryption for SMTP traffic and consider using PGP for end-to-end encryption.