Re: [PATCH 1/2] clocksource: Add Ralink System Tick Counter driver

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi Daniel,

Thanks for reviewing this.

On Mon, Oct 28, 2024 at 5:29 PM Daniel Lezcano
<daniel.lezcano@xxxxxxxxxx> wrote:
>
> On 20/09/2024 09:53, Sergio Paracuellos wrote:
> > System Tick Counter is present on Ralink SoCs RT3352 and MT7620. This
> > driver has been in 'arch/mips/ralink' directory since the beggining of
> > Ralink architecture support. However, it can be moved into a more proper
> > place in 'drivers/clocksource'. Hence add it here adding also support for
> > compile test targets.
> >
> > Signed-off-by: Sergio Paracuellos <sergio.paracuellos@xxxxxxxxx>
> > ---
> >   drivers/clocksource/Kconfig        |  10 ++
> >   drivers/clocksource/Makefile       |   1 +
> >   drivers/clocksource/timer-ralink.c | 150 +++++++++++++++++++++++++++++
> >   3 files changed, 161 insertions(+)
> >   create mode 100644 drivers/clocksource/timer-ralink.c
> >
> > diff --git a/drivers/clocksource/Kconfig b/drivers/clocksource/Kconfig
> > index 95dd4660b5b6..50339f4d3201 100644
> > --- a/drivers/clocksource/Kconfig
> > +++ b/drivers/clocksource/Kconfig
> > @@ -753,4 +753,14 @@ config EP93XX_TIMER
> >         Enables support for the Cirrus Logic timer block
> >         EP93XX.
> >
> > +config CLKSRC_RALINK
>
> It is a timer
>
>         RALINK_TIMER

Sure, I will change to RALINK_TIMER instead.

>
> > +     bool "Ralink System Tick Counter"
>
> Silent option please if possible.
>
> Let the platform Kconfig selects the driver
>
> > +     depends on SOC_RT305X || SOC_MT7620 || COMPILE_TEST
> > +     default y if SOC_RT305X || SOC_MT7620
>
> You should have something similar the RISCV option, no default option

Sorry, I am not the best with Kconfig so I am not sure what you are
exactly expecting here.
Does the following work for you?

config RALINK_TIMER
   bool "Ralink System Tick Counter" if COMPILE_TEST
   depends on SOC_RT305X || SOC_MT7620
   select CLKSRC_MMIO
   select TIMER_OF
   help
     Enables support for system tick counter present on
     Ralink SoCs RT3352 and MT7620.


>
> > +     select CLKSRC_MMIO
> > +     select TIMER_OF
> > +     help
> > +       Enables support for system tick counter present on
> > +       Ralink SoCs RT3352 and MT7620.
> > +
> >   endmenu
> > diff --git a/drivers/clocksource/Makefile b/drivers/clocksource/Makefile
> > index 22743785299e..c9214afcb712 100644
> > --- a/drivers/clocksource/Makefile
>
> You should use git mv
>
> Otherwise the code is like submitting a new driver

Ok, i will squash two patches in one performing the git mv then.

Thanks,
    Sergio Paracuellos
>
>
>
> --
> <http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs
>
> Follow Linaro:  <http://www.facebook.com/pages/Linaro> Facebook |
> <http://twitter.com/#!/linaroorg> Twitter |
> <http://www.linaro.org/linaro-blog/> Blog





[Index of Archives]     [LKML Archive]     [Linux ARM Kernel]     [Linux ARM]     [Git]     [Yosemite News]     [Linux SCSI]     [Linux Hams]

  Powered by Linux