Re: [PATCH v3 2/9] clk: ralink: add clock and reset driver for MTMIPS SoCs

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 17/06/2023 15:26, Sergio Paracuellos wrote:
>>> void __init plat_time_init(void)
>>> {
>>> +      struct of_phandle_args clkspec;
>>>       struct clk *clk;
>>> +      int cpu_clk_idx;
>>>
>>>       ralink_of_remap();
>>>
>>> -      ralink_clk_init();
>>> -      clk = clk_get_sys("cpu", NULL);
>>> +      cpu_clk_idx = clk_cpu_index();
>>> +      if (cpu_clk_idx == -1)
>>> +              panic("unable to get CPU clock index");
>>> +
>>> +      of_clk_init(NULL);
>>> +      clkspec.np = of_find_node_by_name(NULL, "sysc");
>>
>> The node name should be "syscon" as the example node name in the
>> dt-bindings document is "syscon".
> 
> sysc is label to get this node since it is the one shared by all
> different dtsi files.

If it is label, why do you use it to get by name? name != label.

Best regards,
Krzysztof