在 2020/11/3 11:15, Tiezhu Yang 写道:
In loongson3_type3_play_dead(), in order to make sure the PC address is
correct, use lw to read the low 32 bits first, if the result is not zero,
then use ld to read the whole 64 bits, otherwise there maybe exists atomic
problem due to write high 32 bits first and then low 32 bits, like this:
high 32 bits (write done)
-- only read high 32-bits which is wrong
low 32 bits (not yet write done)
This problem is especially for Loongson 3A4000+ CPU due to using Mail_Send
register which can only send 32 bits data one time. Although it is hard to
reproduce, we can do something at the software level to avoid the risks for
3A4000+ CPU, this change has no influence on the other Loongson CPUs.
Signed-off-by: Lu Zeng <zenglu@xxxxxxxxxxx>
Signed-off-by: Jun Yi <yijun@xxxxxxxxxxx>
Signed-off-by: Tiezhu Yang <yangtiezhu@xxxxxxxxxxx>
Hi Tiezhu,
Sorry that I didn't look this patch carefully in previous rev, here's my
comments,
Firstly the commit message and code comment looks bogus...
I'd prefer
---
MIPS: Loongson64: SMP: Fix up play_dead jump indicator
In play_dead function, the whole 64-bit PC mailbox was used as a indicator
to determine if the master core had written boot jump information.
However, after we introduced CSR mailsend, the 64-bit PC mailbox won't be
written atomicly. Thus we have to use the lower 32-bit, which will be
written at
the last, as the jump indicator instead.
--
Thanks.
---
v2: No changes
arch/mips/loongson64/smp.c | 3 ++-
1 file changed, 2 insertions(+), 1 deletion(-)
diff --git a/arch/mips/loongson64/smp.c b/arch/mips/loongson64/smp.c
index 736e98d..e32b46e 100644
--- a/arch/mips/loongson64/smp.c
+++ b/arch/mips/loongson64/smp.c
@@ -764,9 +764,10 @@ static void loongson3_type3_play_dead(int *state_addr)
"1: li %[count], 0x100 \n" /* wait for init loop */
"2: bnez %[count], 2b \n" /* limit mailbox access */
" addiu %[count], -1 \n"
- " ld %[initfunc], 0x20(%[base]) \n" /* get PC via mailbox */
+ " lw %[initfunc], 0x20(%[base]) \n" /* get PC (low 32 bits) via mailbox */
Here you can comment as "Check jump indicator (lower 32-bit of PC mailbox)"
Thanks.
- Jiaxun
" beqz %[initfunc], 1b \n"
" nop \n"
+ " ld %[initfunc], 0x20(%[base]) \n" /* get PC (whole 64 bits) via mailbox */
" ld $sp, 0x28(%[base]) \n" /* get SP via mailbox */
" ld $gp, 0x30(%[base]) \n" /* get GP via mailbox */
" ld $a1, 0x38(%[base]) \n"