Baikal-T1 PVT sensor has got a dedicated power domain with 1.8V intended to be supplied via the external GPVT and VPVT_18 pins. In case if the power isn't supplied, the sensor IO registers will be accessible, but the data conversion just won't happen. The situation of the power loss currently will cause the temperature and voltage read procedures to hang up. The problem is fixed in the framework of this patchset firstly by checking whether the conversion works at the sensor probe procedure, and secondly by keeping the current conversion update timeout in the private driver data cache and using it to set the wait-completion timeout. Fixes: 87976ce2825d ("hwmon: Add Baikal-T1 PVT sensor driver") Signed-off-by: Serge Semin <Sergey.Semin@xxxxxxxxxxxxxxxxxxxx> Cc: Maxim Kaurkin <Maxim.Kaurkin@xxxxxxxxxxxxxxxxxxxx> Cc: Alexey Malahov <Alexey.Malahov@xxxxxxxxxxxxxxxxxxxx> Cc: Pavel Parkhomenko <Pavel.Parkhomenko@xxxxxxxxxxxxxxxxxxxx> Cc: linux-mips@xxxxxxxxxxxxxxx Cc: linux-hwmon@xxxxxxxxxxxxxxx Cc: linux-kernel@xxxxxxxxxxxxxxx Serge Semin (3): hwmon: bt1-pvt: Test sensor power supply on probe hwmon: bt1-pvt: Cache current update timeout hwmon: bt1-pvt: Wait for the completion with timeout drivers/hwmon/bt1-pvt.c | 138 ++++++++++++++++++++++++++++------------ drivers/hwmon/bt1-pvt.h | 3 + 2 files changed, 101 insertions(+), 40 deletions(-) -- 2.27.0