mceusb Fintek ir transmitter only works when X is not running

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi,

I have a HP MCE ir transreceiver which is recognised as Fintek device.
The receiver works fine, however the transmitter only works when there
is no X session running.


When X is stopped and the following command is issued from the virtual
console (tty1), then the transmitter works:

irsend SEND_ONCE mceusb KEY_1


However, as soon as X is started even though irsend goes through, the
transmitter led's dont go through. Any idea why this may be happening?



These are the system details:
#uname -a
Linux localhost 3.10.4-gentoo #7 SMP Sun Aug 4 12:07:08 BST 2013
x86_64 Intel(R) Core(TM) i5 CPU M 520 @ 2.40GHz GenuineIntel GNU/Linux

# lsusb
Bus 002 Device 008: ID 1934:5168 Feature Integration Technology Inc.
(Fintek) F71610A or F71612A Consumer Infrared Receiver/Transceiver

#cat /etc/conf.d/lircd
LIRCD_OPTS="-d /dev/lirc0"


Thanks
Rajil
--
To unsubscribe from this list: send the line "unsubscribe linux-media" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html