Hejssan, On Thu, Dec 12, 2024 at 11:04:45AM +0100, Niklas Söderlund wrote: > Hej Sakari, > > On 2024-12-12 07:20:15 +0000, Sakari Ailus wrote: > > Hej Niklas, > > > > On Tue, Dec 10, 2024 at 04:54:00PM +0100, Niklas Söderlund wrote: > > > The latest datasheet (Rev.0.70) updates the D-PHY start-up sequence for > > > D-PHY operation. Unfortunately the datasheet do not add any additional > > > documentation on the magic values. > > > > > > This have been tested together with the MAX96724 available on the single > > > board test platform and it works as expected. > > > > > > Signed-off-by: Niklas Söderlund <niklas.soderlund+renesas@xxxxxxxxxxxx> > > > > This looks like a fix. Is there a need to backport it? > > It's an update to the start-up sequence. Both the old and new sequence > works in testing. As the datasheet don't document the magic values it's > hard to tell if this is a real fix or not. > > On the other hand, the DTS changes needed to use this device on R-Car > V4M are still pending upstream merge so we have no in-tree users of this > device. I don't think we need to backport this change. Ack. Thanks for confirming this. -- Sakari Ailus