Hi On Thu, 14 Nov 2024 at 21:16, Gergo Koteles <soyer@xxxxxx> wrote: > > Hi Ricardo, > > On Thu, 2024-11-14 at 21:03 +0100, Ricardo Ribalda wrote: > > Hi Gergo > > > > Sorry, I forgot to reply to your comment in v14. > > > > On Thu, 14 Nov 2024 at 20:53, Gergo Koteles <soyer@xxxxxx> wrote: > > > > > > Hi Ricardo, > > > > > > On Thu, 2024-11-14 at 19:10 +0000, Ricardo Ribalda wrote: > > > > > > > > + }, > > > > + { > > > > + .id = V4L2_CID_UVC_REGION_OF_INTEREST_AUTO, > > > > + .entity = UVC_GUID_UVC_CAMERA, > > > > + .selector = UVC_CT_REGION_OF_INTEREST_CONTROL, > > > > + .size = 16, > > > > + .offset = 64, > > > > + .v4l2_type = V4L2_CTRL_TYPE_BITMASK, > > > > + .data_type = UVC_CTRL_DATA_TYPE_BITMASK, > > > > + .name = "Region Of Interest Auto Controls", > > > > + }, > > > > }; > > > > > > > > > > Wouldn't be better to use 8 V4L2_CTRL_TYPE_BOOLEAN controls for this? > > > > If I create 8 Booleans, they will always be shown in the device. And > > the user will not have a way to know which values are available and > > which are not. > > > > We will also fail the v4l2-compliance test, because there will be up > > to 7 boolean controls that will not be able to be set to 1, eventhough > > they are writable. > > > > And can't it be that only those returned by GET_MAX be added? > > ``` > The bmAutoControls bitmask determines which, if any, on board features > should track to the region of interest. To detect if a device supports > a particular Auto Control, use GET_MAX which returns a mask indicating > all supported Auto Controls. > ``` > > Sorry for the misunderstanding, I just don't quite understand. I guess we could, but we would have to make a big change in the way the controls are probed today. uvc does not use the control framework. What will be the benefit of using 8 controls? - Applications still have to know what those controls do, they should not rely on the control name. - Changing from lets say AUTO_EXPOSURE to AUTO_FOCUS, will require to send at least 2 controls via v4l2_s_ext_control... I think it is more practical and less prone to errrors to send just one control If the number of autos were unknown, then having multiple controls could be a good idea, but they are part of the uvc standard and unlikely to be changed. Thanks! > > Thanks, > > Gergo -- Ricardo Ribalda