On Wed, Nov 29, 2023 at 09:13:36AM +0000, Sean Young wrote: > clk_get_rate() may do a mutex lock. Fetch the clock rate once, and prevent > rate changes using clk_rate_exclusive_get(). > > Signed-off-by: Sean Young <sean@xxxxxxxx> > --- > drivers/pwm/pwm-bcm2835.c | 31 +++++++++++++++++++++---------- > 1 file changed, 21 insertions(+), 10 deletions(-) s/pwm/PWM/ in the subject. Although, I guess you could just drop the "PWM" altogether because the subject prefix implies that this is for PWM. Also, please capitalize after the subject prefix. Thierry