18.08.2021 07:31, Viresh Kumar пишет: > On 18-08-21, 07:12, Dmitry Osipenko wrote: >> 18.08.2021 06:55, Viresh Kumar пишет: >>> On 17-08-21, 18:49, Dmitry Osipenko wrote: >>>> 17.08.2021 10:55, Viresh Kumar пишет: >>>> ... >>>>>> +int dev_pm_opp_sync(struct device *dev) >>>>>> +{ >>>>>> + struct opp_table *opp_table; >>>>>> + struct dev_pm_opp *opp; >>>>>> + int ret = 0; >>>>>> + >>>>>> + /* Device may not have OPP table */ >>>>>> + opp_table = _find_opp_table(dev); >>>>>> + if (IS_ERR(opp_table)) >>>>>> + return 0; >>>>>> + >>>>>> + if (!_get_opp_count(opp_table)) >>>>>> + goto put_table; >>>>>> + >>>>>> + opp = _find_current_opp(dev, opp_table); >>>>>> + ret = _set_opp(dev, opp_table, opp, opp->rate); >>>>> >>>>> And I am not sure how this will end up working, since new OPP will be >>>>> equal to old one. Since I see you call this from resume() at many >>>>> places. >>>> >>>> Initially OPP table is "uninitialized" and opp_table->enabled=false, >>>> hence the first sync always works even if OPP is equal to old one. Once >>>> OPP has been synced, all further syncs are NO-OPs, hence it doesn't >>>> matter how many times syncing is called. >>>> >>>> https://elixir.bootlin.com/linux/v5.14-rc6/source/drivers/opp/core.c#L1012 >>> >>> Right, but how will this work from Resume ? Won't that be a no-op ? >> >> The first resume initializes the OPP state on sync, all further syncs on >> resume are no-ops. > > But the OPPs should already be initialized as someone must have called > opp-set-rate earlier ? Why do this from resume and not probe ? This will set voltage level without having an actively used hardware. Take a 3d driver for example, if you set the rate on probe and rpm-resume will never be called, then the voltage will be set high, while hardware is kept suspended if userspace will never wake it up by executing a 3d job.