Hey Andrey, > > On 17.02.2021 14:21, Robert Foss wrote: > > For Titan ISPs clocks fail to re-enable during vfe_get() > > after any vfe has been halted and its corresponding power > > domain power has been detached. > > OK. > > > Since all of the clocks depend on all of the PDs, per > > VFE PD detaching is no option for this generation of HW. > > But this patch removes camss_pm_domain_on/off calls from > vfe_get/put() for all the SOCs, not only for sdm845. > And this looks like a regression (higher power consumption) > for all the generation1 devices. Yeah, that is a serious problem with the approach I picked here. The power difference shouldn't be huge however, since the best case scenario savings of the previous implementation was being able to power down 1 VFE when the other one is working. If none of the VFEs is working, nothing is powered up both in the previous implementation & using this patch. > > Is it possible to handle gen1 and gen2 hardware differently, > so that gen1 continued to use camss_pm_domain_on/off as > before? I hesitated going down this gen1/gen2 split here, due to how deep into the common code some of this functionality is. Let me have another look at this though, not having a power regression for gen1 devices would definitely be preferable.