Hi Steve, On Wed, 2018-08-01 at 12:12 -0700, Steve Longerbeam wrote: > When the CSI is receiving from a bt.656 bus, include a check for > field type 'alternate' when determining whether to set CSI clock > mode to CCIR656_INTERLACED or CCIR656_PROGRESSIVE. > > Signed-off-by: Steve Longerbeam <steve_longerbeam@xxxxxxxxxx> > --- > drivers/gpu/ipu-v3/ipu-csi.c | 3 ++- > 1 file changed, 2 insertions(+), 1 deletion(-) > > diff --git a/drivers/gpu/ipu-v3/ipu-csi.c b/drivers/gpu/ipu-v3/ipu-csi.c > index caa05b0..5450a2d 100644 > --- a/drivers/gpu/ipu-v3/ipu-csi.c > +++ b/drivers/gpu/ipu-v3/ipu-csi.c > @@ -339,7 +339,8 @@ static void fill_csi_bus_cfg(struct ipu_csi_bus_config *csicfg, > break; > case V4L2_MBUS_BT656: > csicfg->ext_vsync = 0; > - if (V4L2_FIELD_HAS_BOTH(mbus_fmt->field)) > + if (V4L2_FIELD_HAS_BOTH(mbus_fmt->field) || > + mbus_fmt->field == V4L2_FIELD_ALTERNATE) > csicfg->clk_mode = IPU_CSI_CLK_MODE_CCIR656_INTERLACED; > else > csicfg->clk_mode = IPU_CSI_CLK_MODE_CCIR656_PROGRESSIVE; this patch is already merged in v4.18-rc7. regards Philipp