Hi Fabio,
Thanks for the review.
On Mon 23 Apr 2018 at 14:11, Fabio Estevam wrote:
Hi Rui,
On Thu, Apr 19, 2018 at 8:00 AM, Rui Miguel Silva
<rui.silva@xxxxxxxxxx> wrote:
+Optional Properties:
+- powerdown-gpios: reference to the GPIO connected to the
powerdown pin,
+ if any. This is an active high signal to
the OV2680.
I looked at the OV2680 datasheet and I see a pin called XSHUTDN,
which has
the following description:
XSHUTDN: reset and power down (active low with internal pull
down resistor)
So it should be active low, not active high.
Yes, you are correct, I will fix this, and the dts entry.
Thanks.
---
Cheers,
Rui