Re: [RFC v2] Another approach to IR

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Dmitry Torokhov wrote:
>> The raw interface applies only to the devices that doesn't have a hardware decoder
>> (something between 40%-60% of the currently supported devices).
> 
> 50% is quite a number I think. But if driver does not allow access to
> the raw stream - it will refuse binding to lirc_dev interface.

Ok.

> We need to cater to the future cases as well. I don't want to redesign
> it in 2 years. But for devices that have only hardware decoders I
> suppose we can short-curcuit "interfaces" and have a library-like module
> creating input devices directly.

We really need only one interface for those devices. However, protocol selection
is needed, as it is associated with the scantable on those devices.
a sysfs entry would solve this issue.

Also, we need a better schema to cleanup the keycode table. Currently, the only way 
I'm aware is to run a loop from 0 to 65535 associating a scancode to KEY_UNKNOWN or
to KEY_RESERVED.

>> In the case of the cheap devices with just raw interfaces, running in-kernel
>> decoders, while it will work if you create one interface per protocol
>> per IR receiver, this also seems overkill. Why to do that? It sounds that it will
>> just create additional complexity at the kernelspace and at the userspace, since
>> now userspace programs will need to open more than one device to receive the
>> keycodes.
> 
> _Yes_!!! You open as many event devices as there are devices you are
> interested in receiving data from. Multiplexing devices are bad, bad,
> bad. Witness /dev/input/mouse and all the attempts at working around the
> fact that if you have a special driver for one of your devices you
> receive events from the same device through 2 interfaces and all kind of
> "grab", "super-grab", "smart-grab" schemes are born.

The only device that the driver can actually see is the IR receiver. There's no way to
know if there is only one physical IR sending signals to it or several different models,
especially if we consider that programmable IR's can be able even to generate more than one
protocol at the same time, and can emulate other IR types.

You might create some artificial schema to try to deal with different IR's being received
at the same IR receiver, but, IMHO, this will just add a complex abstraction layer.

Also, this won't give any real gain, as either both IR's will generate the same scancodes (and you can't distinguish what IR generated that code), or the scancode is different, and you
can handle it differently.

>>> (for each remote/substream that they can recognize).
>> I'm assuming that, by remote, you're referring to a remote receiver (and not to 
>> the remote itself), right?
> 
> If we could separate by remote transmitter that would be the best I
> think, but I understand that it is rarely possible?

IMHO, the better is to use a separate interface for the IR transmitters,
on the devices that support this feature. There are only a few devices
I'm aware of that are able to transmit IR codes.

Cheers,