Add in some device level sysfs entry descriptions: lunid unique_id path_info raid_bypass_cnt sas_ncq_prio_enable These have already been provided by the driver. Reviewed-by: Scott Benesh <scott.benesh@xxxxxxxxxxxxx> Reviewed-by: Scott Teel <scott.teel@xxxxxxxxxxxxx> Reviewed-by: Mike McGowen <mike.mcgowen@xxxxxxxxxxxxx> Reviewed-by: Kevin Barnett <kevin.barnett@xxxxxxxxxxxxx> Signed-off-by: Don Brace <don.brace@xxxxxxxxxxxxx> --- man4/smartpqi.4 | 91 +++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 91 insertions(+) diff --git a/man4/smartpqi.4 b/man4/smartpqi.4 index 19708a01f531..3de8b0c97423 100644 --- a/man4/smartpqi.4 +++ b/man4/smartpqi.4 @@ -356,6 +356,97 @@ $ \c 0 .EE .in +.TP +.IR /sys/class/scsi_disk/c : b : t : l/device/lunid +The +.I lunid +attribute is read-only. +This attribute contains the SCSI LUN ID for the device. +.IP +For example: +.IP +.in +4n +.EX +$ \c +.B cat /sys/class/scsi_disk/13:1:0:3/device/lunid +0x0300004000000000 +.EE +.in +.TP +.IR /sys/class/scsi_disk/c : b : t : l/device/unique_id +The +.I unique_id +attribute is read-only. +This attribute contains a 16-byte ID that uniquely identifies the device within the controller. +.IP +For example: +.IP +.in +4n +.EX +$ \c +.B cat /sys/class/scsi_disk/13:1:0:3/device/unique_id +600508B1001C6D4723A8E98D704FDB94 +.EE +.in +.TP +.IR /sys/class/scsi_disk/c : b : t : l/device/path_info +The +.I path_info +attribute is read-only. +This attribute contains the c:b:t:l of the device along with the device type and whether the device is Active or Inactive. If the device is an HBA device, +.I path_info +will also display the PORT, BOX, and BAY the device is plugged into. +.IP +For example: +.IP +.in +4n +.EX +$ \c +.B cat /sys/class/scsi_disk/13:1:0:3/device/path_info +[13:1:0:3] Direct-Access Active + +$ \c +.B cat /sys/class/scsi_disk/12:0:9:0/device/path_info +[12:0:9:0] Direct-Access PORT: C1 BOX: 1 BAY: 14 Inactive +[12:0:9:0] Direct-Access PORT: C0 BOX: 1 BAY: 14 Active +.EE +.in +.TP +.IR /sys/class/scsi_disk/13:1:0:3/device/raid_bypass_cnt +The +.I raid_bypass_cnt +attribute is read-only. +This attribute contains the number of I/O requests that have gone through the +ioaccel path for ioaccel-enabled volumes. See the +.BI ssd_smart_path_enabled +disk attribute section for details on ioaccel-enabled volumes. +.IP +For example: +.IP +.in +4n +.EX +$ \c +.B cat /sys/class/scsi_disk/13:1:0:3/device/raid_bypass_cnt +0x300 +.EE +.in +.TP +.IR /sys/class/scsi_disk/13:1:0:3/device/sas_ncq_prio_enable +The +.I sas_ncq_prio_enable +attribute is read/write. +This attribute enables SATA NCQ priority support. +This attribute works only when device has NCQ support and +controller firmware can handle IO with NCQ priority attribute. +.IP +For example: +.IP +.in +4n +.EX +$ \c +.B echo 1 > /sys/class/scsi_disk/13:1:0:3/device/sas_ncq_prio_enable +.EE +.in .SH VERSIONS The .B smartpqi -- 2.42.0.rc2