[PATCH 6/9] bcache: pass queue_limits to blk_mq_alloc_disk

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Pass the queue limits directly to blk_alloc_disk instead of setting them
one at a time.

Signed-off-by: Christoph Hellwig <hch@xxxxxx>
---
 drivers/md/bcache/super.c | 46 ++++++++++++++++++++-------------------
 1 file changed, 24 insertions(+), 22 deletions(-)

diff --git a/drivers/md/bcache/super.c b/drivers/md/bcache/super.c
index 9955ecff383966..d06a9649d30269 100644
--- a/drivers/md/bcache/super.c
+++ b/drivers/md/bcache/super.c
@@ -900,6 +900,16 @@ static int bcache_device_init(struct bcache_device *d, unsigned int block_size,
 	struct request_queue *q;
 	const size_t max_stripes = min_t(size_t, INT_MAX,
 					 SIZE_MAX / sizeof(atomic_t));
+	struct queue_limits lim = {
+		.max_hw_sectors		= UINT_MAX,
+		.max_sectors		= UINT_MAX,
+		.max_segment_size	= UINT_MAX,
+		.max_segments		= BIO_MAX_VECS,
+		.max_hw_discard_sectors	= UINT_MAX,
+		.io_min			= block_size,
+		.logical_block_size	= block_size,
+		.physical_block_size	= block_size,
+	};
 	uint64_t n;
 	int idx;
 
@@ -935,7 +945,20 @@ static int bcache_device_init(struct bcache_device *d, unsigned int block_size,
 			BIOSET_NEED_BVECS|BIOSET_NEED_RESCUER))
 		goto out_ida_remove;
 
-	d->disk = blk_alloc_disk(NULL, NUMA_NO_NODE);
+	if (lim.logical_block_size > PAGE_SIZE && cached_bdev) {
+		/*
+		 * This should only happen with BCACHE_SB_VERSION_BDEV.
+		 * Block/page size is checked for BCACHE_SB_VERSION_CDEV.
+		 */
+		pr_info("bcache%i: sb/logical block size (%u) greater than page size (%lu) falling back to device logical block size (%u)\n",
+			idx, lim.logical_block_size,
+			PAGE_SIZE, bdev_logical_block_size(cached_bdev));
+
+		/* This also adjusts physical block size/min io size if needed */
+		lim.logical_block_size = bdev_logical_block_size(cached_bdev);
+	}
+
+	d->disk = blk_alloc_disk(&lim, NUMA_NO_NODE);
 	if (IS_ERR(d->disk))
 		goto out_bioset_exit;
 
@@ -949,27 +972,6 @@ static int bcache_device_init(struct bcache_device *d, unsigned int block_size,
 	d->disk->private_data	= d;
 
 	q = d->disk->queue;
-	q->limits.max_hw_sectors	= UINT_MAX;
-	q->limits.max_sectors		= UINT_MAX;
-	q->limits.max_segment_size	= UINT_MAX;
-	q->limits.max_segments		= BIO_MAX_VECS;
-	blk_queue_max_discard_sectors(q, UINT_MAX);
-	q->limits.io_min		= block_size;
-	q->limits.logical_block_size	= block_size;
-	q->limits.physical_block_size	= block_size;
-
-	if (q->limits.logical_block_size > PAGE_SIZE && cached_bdev) {
-		/*
-		 * This should only happen with BCACHE_SB_VERSION_BDEV.
-		 * Block/page size is checked for BCACHE_SB_VERSION_CDEV.
-		 */
-		pr_info("%s: sb/logical block size (%u) greater than page size (%lu) falling back to device logical block size (%u)\n",
-			d->disk->disk_name, q->limits.logical_block_size,
-			PAGE_SIZE, bdev_logical_block_size(cached_bdev));
-
-		/* This also adjusts physical block size/min io size if needed */
-		blk_queue_logical_block_size(q, bdev_logical_block_size(cached_bdev));
-	}
 
 	blk_queue_flag_set(QUEUE_FLAG_NONROT, d->disk->queue);
 
-- 
2.39.2





[Index of Archives]     [Video for Linux]     [Yosemite News]     [Linux S/390]     [Linux Kernel]     [Linux SCSI]

  Powered by Linux