On 19/09/2024 15:17, Dzmitry Sankouski wrote: >>> + pmic@60 { >>> + compatible = "samsung,s2dos05"; >>> + reg = <0x60>; >>> + >>> + regulators { >>> + s2dos05_ldo1: ldo1 { >>> + regulator-active-discharge = <1>; >>> + regulator-enable-ramp-delay = <12000>; >>> + regulator-min-microvolt = <1500000>; >>> + regulator-max-microvolt = <2000000>; >>> + regulator-name = "s2dos05-ldo1"; >> >> Useless name. Please use rather names from the schematics, but I guess >> you might not have them, so maybe downstream has reasonable name? > > Unfortunately, downstream uses that same name. Then "ldo1" is enough. Best regards, Krzysztof