On Fri, 05 Jul 2024 15:55:01 +0800, Fenglin Wu wrote: > The flash module has status bits to indicate different thermal > conditions which are called as OTSTx. For each OTSTx status, > there is a recommended total flash current for all channels to > prevent the flash module entering into higher thermal level. > For example, the total flash current should be limited to 1000mA/500mA > respectively when the HW reaches the OTST1/OTST2 thermal level. > > [...] Applied, thanks! [1/1] leds: flash: leds-qcom-flash: limit LED current based on thermal condition commit: 3db5127c28f8faa1c245588ab982f72d033e1de4 -- Lee Jones [李琼斯]