On 29.07.2021 17:12:46, Dan Carpenter wrote: > The hi3110_cmd() is supposed to return zero on success and negative > error codes on failure, but it was accidentally declared as a u8 when > it needs to be an int type. > > Fixes: 57e83fb9b746 ("can: hi311x: Add Holt HI-311x CAN driver") > Signed-off-by: Dan Carpenter <dan.carpenter@xxxxxxxxxx> Applied to linux-can/testing. Thanks, Marc -- Pengutronix e.K. | Marc Kleine-Budde | Embedded Linux | https://www.pengutronix.de | Vertretung West/Dortmund | Phone: +49-231-2826-924 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |