On Mon, 09 Nov 2020 14:27:52 +0100 Kurt Kanzenbach wrote: > On Mon Nov 09 2020, Colin King wrote: > > From: Colin Ian King <colin.king@xxxxxxxxxxxxx> > > > > The left shift of u16 variable high is promoted to the type int and > > then sign extended to a 64 bit u64 value. If the top bit of high is > > set then the upper 32 bits of the result end up being set by the > > sign extension. Fix this by explicitly casting the value in high to > > a u64 before left shifting by 16 places. > > > > Also, remove the initialisation of variable value to 0 at the start > > of each loop iteration as the value is never read and hence the > > assignment it is redundant. > > > > Addresses-Coverity: ("Unintended sign extension") > > Fixes: e4b27ebc780f ("net: dsa: Add DSA driver for Hirschmann Hellcreek switches") > > Signed-off-by: Colin Ian King <colin.king@xxxxxxxxxxxxx> > > Reviewed-by: Kurt Kanzenbach <kurt@xxxxxxxxxxxxx> Applied, thanks!