On 8/17/2023 10:19 AM, Mimi Zohar wrote:
Before we can introduce this sort of change, we would need to introduce
an IMA measurement list version. Perhaps its time to define an IMA
security critical-data record, which would include this and other
information. The measurement list itself would need to include a
version number.
FYI, the TCG specified UEFI event log has a standard first record. The
events themselves do not have a version number.
That first record is itself versioned, so it can change over time.
The record has various version numbers, a count of PCR banks, a mapping
from algorithm number to algorithm size, and a sized vendor specific area.