On Tue, 29 Jun 2021, Dmitry Torokhov wrote: > The power supply states of discharging, charging, full, etc, represent > state of charging, not the capacity level of the battery (for which > we have a separate property). Current HID usage tables to not allow > for expressing charging state of the batteries found in generic > styli, so we should simply assume that the battery is discharging > even if current capacity is at 100% when battery strength reporting > is done via HID interface. In fact, we were doing just that before > commit 581c4484769e. > > This change helps UIs to not mis-represent fully charged batteries in > styli as being charging/topping-off. > > Fixes: 581c4484769e ("HID: input: map digitizer battery usage") > Reported-by: Kenneth Albanowski <kenalba@xxxxxxxxxx> > Signed-off-by: Dmitry Torokhov <dmitry.torokhov@xxxxxxxxx> As there was no pushback from Bastien, I am queuing this for 5.15. Thanks, -- Jiri Kosina SUSE Labs