On Fri, 2021-05-07 at 12:18 -0700, trix@xxxxxxxxxx wrote: > From: Tom Rix <trix@xxxxxxxxxx> > > Static analysis reports this representative problem > > hid-logitech-hidpp.c:1356:23: warning: Assigned value is > garbage or undefined > hidpp->battery.level = level; > ^ ~~~~~ > > In some cases, 'level' is never set in hidpp20_battery_map_status_voltage() > Since level is not available on all hw, initialize level to unknown. > > Fixes: be281368f297 ("hid-logitech-hidpp: read battery voltage from newer > devices") > Signed-off-by: Tom Rix <trix@xxxxxxxxxx> > --- > drivers/hid/hid-logitech-hidpp.c | 1 + > 1 file changed, 1 insertion(+) > > diff --git a/drivers/hid/hid-logitech-hidpp.c b/drivers/hid/hid-logitech- > hidpp.c > index 69670ca7e1e1..61635e629469 100644 > --- a/drivers/hid/hid-logitech-hidpp.c > +++ b/drivers/hid/hid-logitech-hidpp.c > @@ -1265,6 +1265,7 @@ static int hidpp20_battery_map_status_voltage(u8 > data[3], int *voltage, > int status; > > long flags = (long) data[2]; > + *level = POWER_SUPPLY_CAPACITY_LEVEL_UNKNOWN; > > if (flags & 0x80) > switch (flags & 0x07) { Hi Tom, Taking a look at how this function is used, it does make sense to initialize the level, thank you :) Reviewed-by: Filipe Laíns <lains@xxxxxxxxxx> Cheers, Filipe Laíns
Attachment:
signature.asc
Description: This is a digitally signed message part