Hello Jeff, On Tue, Oct 22, 2019 at 09:45:25PM -0500, Jeff LaBundy wrote: > On Tue, Oct 22, 2019 at 08:54:15AM +0200, Uwe Kleine-König wrote: > > On Mon, Oct 21, 2019 at 11:36:49PM -0500, Jeff LaBundy wrote: > > > On Mon, Oct 21, 2019 at 09:34:19AM +0200, Uwe Kleine-König wrote: > > > > > +{ > > > > > + struct iqs620_pwm_private *iqs620_pwm; > > > > > + struct iqs62x_core *iqs62x; > > > > > + int error; > > > > > + int duty_calc = state->duty_cycle * 256 / IQS620_PWM_PERIOD_NS - 1; > > > > > + u8 duty_clamp = clamp(duty_calc, 0, 0xFF); > > > > Another problem that we have here is that the period is fixed to 1 ms > > and if a consumer requests for example: > > > > .period = 5000000, > > .duty_cycle = 1000000, > > > > the hardware is actually configured for > > > > .period = 1000000, > > .duty_cycle = 1000000, > > > > . I don't have a good suggestion how to fix this. We'd need to > > draw a line somewhere and decline a request that is too far from the > > result. But where this line should be is not obvious, it should > > definitively not be implemented in the driver itself IMHO. > > > > (The only halfway sane approach would be to let lowlevel drivers > > implement a .round_state callback and then let the framework judge. But > > we're a long way from having that, so that's not a solution for today.) > > > > Agreed on all counts. For now, I will mention in the 'Limitations' heading that > the period cannot be adjusted. Ack. My longterm plan is to require .apply_state() to round down both .period and .duty_cycle. This isn't wrong already today, so I suggest you decline a request to set the period to something smaller than 1 ms with an error code. (I think most drivers use -EINVAL here, conceptually -EDOM might be sensible. I'd stick to EINVAL for now.) > > > > > + iqs620_pwm = container_of(chip, struct iqs620_pwm_private, chip); > > > > > + iqs62x = iqs620_pwm->iqs62x; > > > > > + > > > > > + error = regmap_write(iqs62x->map, IQS620_PWM_DUTY_CYCLE, duty_clamp); > > > > > + if (error) > > > > > + return error; > > > > > + > > > > > + state->period = IQS620_PWM_PERIOD_NS; > > > > > + state->duty_cycle = (duty_clamp + 1) * IQS620_PWM_PERIOD_NS / 256; > > > > > > > > This suggests that if the value in the IQS620_PWM_DUTY_CYCLE is 0 the > > > > duty cycle is 1/256 ms with a period of 1 ms and the output cannot be > > > > constant inactive. If this is right please add a paragraph in the > > > > driver's comment at the top: > > > > > > > > * Limitations: > > > > * - The hardware cannot generate a 0% duty cycle > > > > > > > > (Please stick to this format, other drivers use it, too.) > > > > > > That's correct; the lowest duty cycle that can be achieved using only the > > > IQS620_PWM_DUTY_CYCLE register is 0.4%. We can, however, generate 0% duty > > > cycle by disabling the output altogether using a separate register. Would > > > that be better than flat-out saying it's impossible? > > > > There is (maybe) a small difference between disabled and 0% duty cycle, > > at least from the framework's POV: If you do: > > > > pwm_apply_state(pwm, { .enabled = true, .period = 1000000, .duty_cycle = 1000000, }); > > pwm_apply_state(pwm, { .enabled = false, .period = $DC, .duty_cycle = $DC, }); > > pwm_apply_state(pwm, { .enabled = true, .period = 1000000, .duty_cycle = 1000000, }); > > > > and compare it to the expected result of > > > > pwm_apply_state(pwm, { .enabled = true, .period = 1000000, .duty_cycle = 1000000, }); > > pwm_apply_state(pwm, { .enabled = true, .period = 1000000, .duty_cycle = 0, }); > > pwm_apply_state(pwm, { .enabled = true, .period = 1000000, .duty_cycle = 1000000, }); > > > > the difference is that the duration of the inactive phase in the latter > > case is a multiple of 1 ms. > > > > There is no policy for lowlevel drivers what to do, but disabling when > > 0% is requested is at least not unseen and probably more what consumers > > expect. > > > > With the change I am proposing, the output will be driven to zero if enabled = false > OR duty_cycle < 4000 ns. Stated another way: > > enable duty_cycle IQS620_PWR_SETTINGS[7] IQS620_PWM_DUTY_CYCLE > ------ ---------- ---------------------- --------------------- > 0 don't care 0 don't care > 1 0 ... 3999 0 don't care > 1 4000 ... x 1 0 > 1 x+1 ... y 1 1 > > ...and so on. For context, if IQS620_PWR_SETTINGS[7] = 0 then the output is held to > zero. If IQS620_PWR_SETTINGS[7] = 1 then the output toggles at a duty cycle between > 0.4% and 100% as a function of IQS620_PWM_DUTY_CYCLE. Your table isn't accurate. IQS620_PWM_DUTY_CYCLE=0 results in a duty_cycle of 3906.25 ns so the table should look as follows: enable duty_cycle IQS620_PWR_SETTINGS[7] IQS620_PWM_DUTY_CYCLE ------ ------------ ---------------------- --------------------- 0 don't care 0 don't care 1 [0, 3906] 0 don't care 1 [3907, 7812] 1 0 1 [7813,11718] 1 1 In general: dc = state->duty_cycle * 256 / 1000000 if state->enabled == false or dc == 0: IQS620_PWR_SETTINGS[7] = 0 else: IQS620_PWM_DUTY_CYCLE = min(dc - 1, 0xff) IQS620_PWR_SETTINGS[7] = 1 > Based on how the device behaves in response to its two available > registers, I think your two examples will appear equal, but please let > me know if I have understood. Yeah, that's the expectation. With the rounding as I suggested above this yields strange effects like if .period = 1 s, .duty_cycle = 0.5 s is requested you end up in .period = 1 ms, .duty_cycle = 1 ms but I think there is nothing we can reasonably do about this. Best regards Uwe -- Pengutronix e.K. | Uwe Kleine-König | Industrial Linux Solutions | http://www.pengutronix.de/ |