[PATCH v4 20/20] arm: mach-pxa: Decrement the power supply's device reference counter

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Use power_supply_put() to decrement the power supply's device reference
counter.

Signed-off-by: Krzysztof Kozlowski <k.kozlowski@xxxxxxxxxxx>
Reviewed-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@xxxxxxxxxxx>
Reviewed-by: Sebastian Reichel <sre@xxxxxxxxxx>
Acked-by: Robert Jarzmik <robert.jarzmik@xxxxxxx>
---
 arch/arm/mach-pxa/raumfeld.c | 4 +++-
 1 file changed, 3 insertions(+), 1 deletion(-)

diff --git a/arch/arm/mach-pxa/raumfeld.c b/arch/arm/mach-pxa/raumfeld.c
index a762b23ac830..6dc4f025e674 100644
--- a/arch/arm/mach-pxa/raumfeld.c
+++ b/arch/arm/mach-pxa/raumfeld.c
@@ -758,8 +758,10 @@ static void raumfeld_power_signal_charged(void)
 	struct power_supply *psy =
 		power_supply_get_by_name(raumfeld_power_supplicants[0]);
 
-	if (psy)
+	if (psy) {
 		power_supply_set_battery_charged(psy);
+		power_supply_put(psy);
+	}
 }
 
 static int raumfeld_power_resume(void)
-- 
1.9.1

--
To unsubscribe from this list: send the line "unsubscribe linux-input" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html