Bit 3 in byte 31 of the Sixaxis report indicates whether the battery is charging or not charging as opposed to whether or not the cable is plugged in. As a result, when connected via USB and fully charged, the power_supply status is wrongly reported as 'Discharging' instead of 'Full'. Use the battery level value to set the cable state so that the power status is reported correctly as that seems to be the only reliable way to determine the cable status on the Sixaxis. Signed-off-by: Frank Praznik <frank.praznik@xxxxxxxxx> --- drivers/hid/hid-sony.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-) diff --git a/drivers/hid/hid-sony.c b/drivers/hid/hid-sony.c index c372368..ecc6616 100644 --- a/drivers/hid/hid-sony.c +++ b/drivers/hid/hid-sony.c @@ -935,12 +935,13 @@ static void sixaxis_parse_report(struct sony_sc *sc, __u8 *rd, int size) if (rd[30] >= 0xee) { battery_capacity = 100; battery_charging = !(rd[30] & 0x01); + cable_state = 1; } else { __u8 index = rd[30] <= 5 ? rd[30] : 5; battery_capacity = sixaxis_battery_capacity[index]; battery_charging = 0; + cable_state = 0; } - cable_state = !(rd[31] & 0x04); spin_lock_irqsave(&sc->lock, flags); sc->cable_state = cable_state; -- 1.9.3 -- To unsubscribe from this list: send the line "unsubscribe linux-input" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html