Add a check to ensure that LRA libraries are not mixed with the ERM mode. If ERM mode and the Library is empty "OR" the LRA library then exit. As the LRA and empty libraries are not applicable for the ERM actuator. Signed-off-by: Dan Murphy <dmurphy@xxxxxx> --- drivers/input/misc/drv260x.c | 8 ++++++++ 1 file changed, 8 insertions(+) diff --git a/drivers/input/misc/drv260x.c b/drivers/input/misc/drv260x.c index a7a19e6..d6a26a7 100644 --- a/drivers/input/misc/drv260x.c +++ b/drivers/input/misc/drv260x.c @@ -564,6 +564,14 @@ static int drv260x_probe(struct i2c_client *client, return -EINVAL; } + if (haptics->mode == DRV260X_ERM_MODE && + haptics->library == DRV260X_LIB_EMPTY || + haptics->library == DRV260X_LIB_LRA) { + dev_err(&client->dev, + "ERM Mode with LRA Library mismatch\n"); + return -EINVAL; + } + haptics->regulator = devm_regulator_get(&client->dev, "vbat"); if (IS_ERR(haptics->regulator)) { error = PTR_ERR(haptics->regulator); -- 1.7.9.5 -- To unsubscribe from this list: send the line "unsubscribe linux-input" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html