Hi Alexandre, On Thursday 09 January 2014 14:31:22 Alexandre Belloni wrote: > Sorry to chime in only now but it seems that this series is breaking the > touchscreen calibration on 3.13 (and -rc7 is out so it might be too > late). > > At first, I though I became a terrible clicker ;) but I found some > evidences: > > xinput_calibrator is complaining about misclicks, debug output: > DEBUG: Adding click 0 (X=105, Y=59) > DEBUG: Not adding click 1 (X=100, Y=59): within 7 pixels of previous click > DEBUG: Adding click 1 (X=696, Y=58) > DEBUG: Not adding click 2 (X=700, Y=55): within 7 pixels of previous click > DEBUG: Adding click 2 (X=103, Y=422) > DEBUG: Mis-click detected, click 3 (X=438, Y=415) not aligned with click 1 (X=696, Y=58) or click 2 (X=103, Y=422) (threshold=15) > DEBUG: Adding click 0 (X=424, Y=411) > > Do you see the confusion ? At some point one of the coordinates is not > updated. Successful calibration with 3.12.6 gives: > DEBUG: Adding click 0 (X=126, Y=405) > DEBUG: Adding click 1 (X=684, Y=399) > DEBUG: Adding click 2 (X=128, Y=77) > DEBUG: Adding click 3 (X=683, Y=77) > > > With ts_calibrate: > xres = 800, yres = 480 > Took 1 samples... > Top left : X = 435 Y = 3572 > Took 2 samples... > Top right : X = 2094 Y = 3553 > Took 2 samples... > Bot right : X = 2939 Y = 2077 > Took 2 samples... > Bot left : X = 2060 Y = 644 > Took 2 samples... > Center : X = 1279 Y = 1346 > > We experience the same thing, when changing position on an axis, we get > an average between the previous and the new position (probably because > we got 2 samples): > - Top Left is ok > - Top right is almost ok: X should be around 3500/3700 > - Bot right is starting to get really wrong: X is getting better (it > should still be around 3500/3700) but Y should be quite lower > - Bot left: Y is ok but X should be lower > - Center is completely wrong, both values should be around 2000 > > Last test with evtest which is always difficult because it outputs a lot > of debug. Two separate touchs, bottom left and then top right (note that > this is with fsl,ave-ctrl = <8>;): > > Event: time 1389210862.451000, type 3 (Absolute), code 0 (X), value 2183 > Event: time 1389210862.451000, type 3 (Absolute), code 1 (Y), value 720 > Event: time 1389210862.451000, type 3 (Absolute), code 24 (Pressure), value 6 > Event: time 1389210862.451000, type 1 (Key), code 330 (Touch), value 1 > Event: time 1389210862.451000, -------------- Report Sync ------------ > Event: time 1389210862.477721, type 3 (Absolute), code 0 (X), value 448 > Event: time 1389210862.477721, type 3 (Absolute), code 1 (Y), value 667 > Event: time 1389210862.477721, type 3 (Absolute), code 24 (Pressure), value 595 > Event: time 1389210862.477721, -------------- Report Sync ------------ > Event: time 1389210862.504718, type 3 (Absolute), code 0 (X), value 434 > Event: time 1389210862.504718, type 3 (Absolute), code 1 (Y), value 704 > Event: time 1389210862.504718, type 3 (Absolute), code 24 (Pressure), value 580 > Event: time 1389210862.504718, -------------- Report Sync ------------ > Event: time 1389210862.536688, type 1 (Key), code 330 (Touch), value 0 > Event: time 1389210862.536688, -------------- Report Sync ------------ > Event: time 1389210863.359697, type 3 (Absolute), code 0 (X), value 432 > Event: time 1389210863.359697, type 3 (Absolute), code 1 (Y), value 726 > Event: time 1389210863.359697, type 3 (Absolute), code 24 (Pressure), value 210 > Event: time 1389210863.359697, type 1 (Key), code 330 (Touch), value 1 > Event: time 1389210863.359697, -------------- Report Sync ------------ > Event: time 1389210863.391687, type 1 (Key), code 330 (Touch), value 0 > Event: time 1389210863.391687, -------------- Report Sync ------------ > > We get 3 reports for bottom left, then pen up, then one report for top > right that is almost exactly the same a bottom left ! > > Output from 3.12: > Event: time 1389210022.146809, type 3 (Absolute), code 0 (X), value 286 > Event: time 1389210022.146809, type 3 (Absolute), code 1 (Y), value 504 > Event: time 1389210022.146809, type 3 (Absolute), code 24 (Pressure), value 3045 > Event: time 1389210022.146809, type 1 (Key), code 330 (Touch), value 1 > Event: time 1389210022.146809, -------------- Report Sync ------------ > Event: time 1389210022.166830, type 3 (Absolute), code 0 (X), value 256 > Event: time 1389210022.166830, type 3 (Absolute), code 1 (Y), value 489 > Event: time 1389210022.166830, type 3 (Absolute), code 24 (Pressure), value 3033 > Event: time 1389210022.166830, -------------- Report Sync ------------ > Event: time 1389210022.186812, type 3 (Absolute), code 24 (Pressure), value 0 > Event: time 1389210022.186812, type 1 (Key), code 330 (Touch), value 0 > Event: time 1389210022.186812, -------------- Report Sync ------------ > Event: time 1389210025.196808, type 3 (Absolute), code 0 (X), value 3812 > Event: time 1389210025.196808, type 3 (Absolute), code 1 (Y), value 3637 > Event: time 1389210025.196808, type 3 (Absolute), code 24 (Pressure), value 4032 > Event: time 1389210025.196808, type 1 (Key), code 330 (Touch), value 1 > Event: time 1389210025.196808, -------------- Report Sync ------------ > Event: time 1389210025.216819, type 3 (Absolute), code 24 (Pressure), value 0 > Event: time 1389210025.216819, type 1 (Key), code 330 (Touch), value 0 > Event: time 1389210025.216819, -------------- Report Sync ------------ > > > While this is not necessarily an issue with ts_calibrate (it is possible > to click longer so it collects more samples), I don't see that working > with xinput_calibrator. > > While I don't have much experience with the TS part of the code but I > can investigate if you don't have any idea. You are right. I have seen the same behaviour here a few times. Currently I'm short in time to dig deeper into this issue, but I will try to do so. Juergen -- Pengutronix e.K. | Juergen Beisert | Linux Solutions for Science and Industry | http://www.pengutronix.de/ | -- To unsubscribe from this list: send the line "unsubscribe linux-input" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html