hidinput_calc_abs_res should return the closest int in the division instead of the floor. On a device with a logical_max of 3008 and a physical_max of 255mm, previous implementation gave a resolution of 11 instead of 12. With 11, user-space computes a physical size of 273.5mm and the round_closest results gives 250.6mm. The old implementation introduced an error of 2cm in this example. Signed-off-by: Benjamin Tissoires <benjamin.tissoires@xxxxxxxxx> --- drivers/hid/hid-input.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/hid/hid-input.c b/drivers/hid/hid-input.c index f5b1d57..67044f3 100644 --- a/drivers/hid/hid-input.c +++ b/drivers/hid/hid-input.c @@ -287,7 +287,7 @@ __s32 hidinput_calc_abs_res(const struct hid_field *field, __u16 code) } /* Calculate resolution */ - return logical_extents / physical_extents; + return DIV_ROUND_CLOSEST(logical_extents, physical_extents); } EXPORT_SYMBOL_GPL(hidinput_calc_abs_res); -- 1.7.11.7 -- To unsubscribe from this list: send the line "unsubscribe linux-input" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html