[PATCH 2/4] input - wacom: don't retrieve touch_max when it is predefined

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Some models, such as 0xE6, report more fingers than we process.

Reported-by: Jonathan Nieder <jrnieder@xxxxxxxxx>
Tested-by: Nils Kanning <nils@xxxxxxxxxx>
Signed-off-by: Ping Cheng <pingc@xxxxxxxxx>
---
 drivers/input/tablet/wacom_sys.c |    4 +++-
 1 files changed, 3 insertions(+), 1 deletions(-)

diff --git a/drivers/input/tablet/wacom_sys.c b/drivers/input/tablet/wacom_sys.c
index c2fb698..2714ce6 100644
--- a/drivers/input/tablet/wacom_sys.c
+++ b/drivers/input/tablet/wacom_sys.c
@@ -398,7 +398,9 @@ static int wacom_parse_hid(struct usb_interface *intf,
 				break;
 
 			case HID_USAGE_CONTACTMAX:
-				wacom_retrieve_report_data(intf, features);
+				/* leave touch_max as is if predefined */
+				if (!features->touch_max)
+					wacom_retrieve_report_data(intf, features);
 				i++;
 				break;
 			}
-- 
1.7.7.6

--
To unsubscribe from this list: send the line "unsubscribe linux-input" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html