Re: [PATCH 4/8 v3] Input: synaptics - add image sensor support

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Wed, Aug 17, 2011 at 10:05:48PM +0800, Daniel Kurtz wrote:
> On Mon, Aug 15, 2011 at 3:17 PM, Daniel Kurtz <djkurtz@xxxxxxxxxxxx> wrote:
> >
> > Hi Henrik,
> >
> > Thanks for the great feedback.
> >
> > On Sat, Aug 13, 2011 at 5:09 AM, Henrik Rydberg <rydberg@xxxxxxxxxxx> wrote:
> > > Hi Daniel,
> > >
> > > looks good, some details below.
> > >
> > > The ABS_MT_TOUCH_MAJOR is supposed to have zero intercept, to remain
> > > compatible with user space handling of type A devices. Also, the scale
> > > should match the screen/pad size, such that the actual size of the
> > > touch area can be deduced. In addition, based on the current sensor
> > > technologies, ABS_MT_PRESSURE and ABS_MT_TOUCH_MAJOR are normally
> > > mutually exclusive.
> > >
> > > All in all, I would prefer to only report width via (the single-finger
> > > axis) ABS_TOOL_WIDTH, and only for compatibility reasons.
> > >
> > > +
> > > +static void synaptics_report_slot_agm(struct input_dev *dev, int slot,
> > > +                                   const struct synaptics_hw_state *agm)
> > > +{
> > > +     input_mt_slot(dev, slot);
> > > +     input_mt_report_slot_state(dev, MT_TOOL_FINGER, true);
> > > +     input_report_abs(dev, ABS_MT_POSITION_X, agm->x);
> > > +     input_report_abs(dev, ABS_MT_POSITION_Y, invert_y(agm->y));
> > > +     input_report_abs(dev, ABS_MT_PRESSURE, agm->z);
> > > +}
> >
> > With ABS_MT_TOUCH_MAJOR dropped, sgm and agm seems to coincide...
> > ....
> > >
> > > Looks good otherwise.
> > >
> > > Thanks,
> > > Henrik
> > >
> >
> > Ahh....  ok, this makes sense.  I missed this detail previously.
> > Basically:
> >  * Only report synaptics "w" as ABS_TOOL_WIDTH (for backwards compatibility)
> >  * Report synaptics "z" as ABS_MT_TOUCH_MAJOR (assuming it is really
> > 'width of finger in surface units'), and ABS_PRESSURE (for backwards
> > compatibility).
> >  * Don't use ABS_MT_PRESSURE.
> >  * This will simplify agm/sgm reporting by making them both reoprt
> > the same axes.
> 
> Hi Henrik,
> 
> I think I was wrong in my previous comment.
> 
> I agree we should drop reporting synaptics 'w' (4-15, arbitrary units)
> in ABS_MT_TOUCH_MAJOR.
> Instead, to support legacy, report 'w' in ABS_TOOL_WIDTH, and do not
> report ABS_MT_TOUCH_MAJOR at all.
> 
> However, I believe we should still report synaptics 'z' (0-255, in
> arbitrary units) as ABS_MT_PRESSURE.
> This will, in turn, be used by input_mt_report_pointer_emulation() to
> determine the correct ABS_PRESSURE to report for legacy userspace
> uses.

Alternatively, you can use input_mt_set_value() to save Z value to be
used by input_mt_report_pointer_emulation() later, but not report it as
part of MT packet.

-- 
Dmitry
--
To unsubscribe from this list: send the line "unsubscribe linux-input" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html


[Index of Archives]     [Linux Media Devel]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]     [Linux Wireless Networking]     [Linux Omap]